More info
Description / Abstract:
This test method provides a procedure for the determination of
the water absorption by a core of concrete taken from a surface
treated with a water repellent.
The intended use of the water repellent coating is to reduce the
amount of water that absorbs into the substrate.
The values stated in SI units are to be regarded as the
standard. The values given in parentheses are for information
only.
This standard does not purport to address all of the safety
concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety and
health practices and determine the applicability of regulatory
limitations prior to use.