Description / Abstract:
This practice covers acceptance criteria for visual inspectionof
parts made from molded glass-reinforced plasticlaminates.
This practice presents word descriptions of possibledefects to
serve as a guide for contracts, drawings, productspecifications,
and final inspection.
This practice also categorizes different inspection
requirementsfor levels of product quality.
The allowable size and frequency of permitted defectswithin the
acceptance level categories of this specification aregeneral and
not related to specific service requirements. ALevel IV of
allowable defects which defines allowable size,frequency, and
permitted repair procedures should be establishedfor specific
service requirements as agreed upon betweenthe purchaser and the
supplier.
The values stated in SI units are to be regarded as thestandard.
The values given in parentheses are for informationonly.
This standard does not purport
to address all of thesafety concerns, if any, associated with its
use. It is theresponsibility of the user of this standard to
establish appropriatesafety and health practices and determine the
applicabilityof regulatory limitations prior to use.
NOTE 1—There is no known ISO equivalent to this standard.