More info
Description / Abstract:
This test method provides procedures for the leak testing of
tubing using pneumatic pressure. This test method involves
measuring the change in pressure inside the tubing over time. There
are three procedures that may be used, all of which are intended to
be equivalent. It is a qualitative not a quantitative test method.
Any of the three procedures are intended to be capable of leak
detection and, as such, are intended to be equivalent for that
purpose.
The procedures will produce consistent results upon which
acceptance standards can be based. This test may be performed in
accordance with the Pressure Differential (Procedure A), the
Pressure Decay (Procedure B), or the Vacuum Decay (Procedure C)
method.
The values stated in either SI units or inch-pound units are to
be regarded separately as standard. The values stated in each
system may not be exact equivalents; therefore, each system shall
be used independently of the other. Combining values from the two
systems may result in non-conformance with the standard.
Within the text, the SI units are shown in brackets.
This standard does not purport to address all of the safety
concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety and
health practices and determine the applicability of regulatory
limitations prior to use.