More info
Description / Abstract:
This Code covers a defined range of primary fuel
characteristics, but is limited to combined-cycle, power-generation
systems using gas and steam turbines.
This Code defines the boundaries of the overall IGCC power plant
to encompass three major plant sections — the air separation unit
(ASU, for oxygen-blown gasifiers or plants that use nitrogen), the
gasification process (including gas cleanup), and the power block.
Tests conducted by this Code determine the quantity and quality of
fuel gas by its flow rate, temperature, pressure, composition,
heating value, and its content of contaminants. Contaminants are
compounds that are potentially deleterious to the gas turbine and
power block in general, or are precursors to stack emissions.
Contaminants to be measured are sodium (Na), potassium (K),
vanadium (V), lead (Pb), calcium (Ca), barium (Ba), manganese (Mn),
phosphorus (P), sulfur compounds (H2S and COS), nitrogen
compounds (HCN and NH3), chlorine compounds (HCl), and
particulate matter.
Recommendations are included for the following in pretest
agreements: testing procedures, types of instruments, methods of
measurement, methods of calculation, and contents of test
reports.
Regulatory compliance testing of IGCC power plants is not
covered by this Code.