Description / Abstract:
This specification describes permitted constituent materials,
limits on constituent volumes, and minimum performance requirements
for carbon and glass fiber-reinforced polymer (FRP) bars to be used
as reinforcement for nonprestressed concrete.
Only carbon and glass FRP bars are covered by this
specification.
FRP bars made of more than one fiber type (hybrid FRP) are not
covered by this specification.
Pultruded FRP bars with no external surface enhancement (that
is, plain or smooth bars) to facilitate bond with concrete are not
covered by this specification. Similarly, hollow FRP bars are not
considered due to lack of documented performance as reinforcement
for concrete.
Plain FRP bars used as dowels (that is, devices that transfer
shear across concrete joints) where the intended function requires
slip of the dowel are not covered by this specification.
This specification does not cover premanufactured grids and
gratings made with FRP materials. FRP mats resulting from assembly
of deformed FRP bars, however, are covered by this document.
This specification does not cover FRP bars when used for
external and near-surface-mounted strengthening applications.
The text of this specification references notes and footnotes
that provide explanatory material. These notes and footnotes
(excluding those in tables and figures) shall not be considered as
requirements of the specification.