More info
Description / Abstract:
Work specified—This specification sets the minimum
requirements for testing of ready mixed concrete at the project
site when specific field-measured properties and
laboratory-measured compressive strength are used as a basis for
acceptance of concrete as delivered to the site. It includes
requirements for making and curing test specimens, performing field
and laboratory tests, and qualifying personnel and laboratories
performing these tests. Testing services required in this
specification shall be completed by a Testing Agency engaged by the
Owner. The Testing Agency must be independent from conflicts of
interest that may affect objective reporting of the testing
services.
Work not specified—This specification does not apply to
testing requirements and responsibilities required of the
construction Contractor.
Project Documents—The Testing Agency shall provide the
tests and reports defined by the Project Specifications supplied by
the Owner or Owner's representative.