Description / Abstract:
This guide includes a discussion of the material characteristics
of ASTM A1035/A1035M steel bars and recommends design criteria for
beams, columns, slab systems, walls, and footings for Seismic
Design Category (SDC) A, B, or C. For a lack of adequate data, the
application of this guide for SDC D, E, or F is limited to slab
systems, foundations, and structural components not designated as
part of the seismicforce- resisting system but explicitly checked
for the induced effects of the design displacements. The only
exception is the use of transverse reinforcement for concrete
confinement with a specified yield strength,
fy, up to 100,000 psi (690 MPa) for
special moment frames, special structural walls, and coupling beams
as permitted by Section 21.1.5.4 of ACI 318-08. Refer to Section
10.1 of this guide for more information on seismic design
considerations. Shells and folded plate members and prestressed
concrete are beyond the scope of this guide. Design examples are
included to illustrate design procedures and proper application of
the design criteria. Modifications to these design criteria may be
justified where the design adequacy within the scope of this guide
is demonstrated by successful use, analysis, or test.