More info
Description / Abstract:
This appendix provides design requirements for anchors in
concrete used to transmit structural loads by means of tension,
shear, or a combination of tension and shear between (a) connected
structural elements; or (b) safety-related attachments and
structural elements. Safety levels specified are intended for
in-service conditions, rather than for short-term handling and
construction conditions.
This appendix applies to both cast-in anchors and post-installed
anchors. Specialty inserts, through bolts, multiple anchors
connected to a single steel plate at the embedded end of the
anchors, adhesive or grouted anchors, and direct anchors such as
powder or pneumatic actuated nails or bolts, are not included.
Reinforcement used as part of the embedment shall be designed in
accordance with other parts of this code.
Headed studs and headed bolts having a geometry that has been
demonstrated to result in a pullout strength in uncracked concrete
equal or exceeding 1.4Np (where Np is given by Eq. (D-15)) are
included. Hooked bolts that have a geometry that has been
demonstrated to result in a pullout strength